After this unit you can
- State the same-input test and apply it to a proposed descriptor
- Reproduce the square–rectangle and shear counterexamples
- Derive the absolute and relative error floors forced by a missing coordinate
- Explain why the answer depends on the lighting family
- Tell an information failure from a failed formula
The same-input test
A descriptor D(g) is whatever a calculation is told about the geometry: dimensions, a frame, a lookup table, coefficients. Calling it sufficient is a claim about a stated task. The paper’s task is transmitted power under a declared family of illuminations.
Definition. D is sufficient if one calculation F gives ℛ(g, L) = F(D(g), L) for every allowed geometry and illumination. Anything shape-specific that F uses counts as input, not as fixed data shared by all shapes.
Proposition 3.2 (identical inputs must require identical answers). A sufficient calculation exists exactly when D(g1) = D(g2) implies ℛ(g1, L) = ℛ(g2, L) for every allowed L.
One direction is obvious: a calculation given the same inputs returns the same output. The other is nearly as short: if every geometry sharing a descriptor needs the same answer, that shared answer is the function F.
So to show a summary is insufficient you need one thing: two openings with the same summary and different required answers under the same light. No amount of fitting, refinement or computing power can then rescue it.
This is not the statistician’s “sufficient statistic”. It is a deterministic test of whether the answer is determined by the inputs. It says nothing about how cheaply the answer can be computed.
The two summaries tested are (n, A, d), meaning normal, area and depth, and the fuller (Q, A, d), which adds the orientation frame.
Counterexample 1: aspect ratio
Use the square and rectangle from Unit 1:
Both have area 1, normal ez, depth 1 and frame Q = I. Both summaries are identical. From s* = (1, 0, 2)/√5 the transmissions are ½ and ¾.
A single ray is not enough, because no real source is one direction. So the paper repeats the test with a uniform circular cone of half-angle 2° around s*. Throughout that cone the rectangle keeps the larger visible fraction, and an analytic bound that needs no numerical integration gives
The exact gap has a closed form and evaluates to about 0.23343384. Numerical integration puts the individual transmissions near 0.49172 and 0.72515. The paper is careful about which of these carries the proof: the inequality does, not confidence in the displayed digits.
How much error is forced
Suppose the true answers are r1 < r2 but the common record forces a single prediction y. Whatever y is, it cannot be closer than half the gap to both:
The midpoint attains it. For relative error the sharp floor is different, and its best prediction is the harmonic mean rather than the midpoint:
Applying the floor
For the 2° cone the gap exceeds 5/32, so any predictor restricted to either summary errs by more than 5/64, which is 7.8125 percentage points, on at least one of the two openings. A one-point target is therefore impossible for it, however it was fitted.
guide exercise For the single ray the answers are 0.50 and 0.75. Absolute floor: 0.125. Relative floor: 0.25/1.25 = 20%, attained by predicting the harmonic mean 0.60.
Counterexample 2: shear
Aspect ratio is not the only thing a frame forgets. Shear the unit square by k = 3/10 as in Unit 1, example 3. Area, depth, normal and frame are unchanged. For the direction proportional to (0.8, 0.4, 1) the visible fractions are 0.120 and 0.192.
- Directional absolute floor: 0.036.
- Directional relative floor: 3/13, about 23.08%.
- For a 2° cone about that direction the proven gap exceeds 0.05, forcing an error above 0.025. Numerical estimates of the two transmissions are 0.1201756880 and 0.1919847478.
Two different omissions, the same information limit. A retained orientation frame repairs neither.
What resolves the ambiguity, and what does not
Shape is not orientation
Unit 1, example 4 showed rolls of a fixed rectangle giving 0.63, 0.38 and 0.63. There the frame changes, so (Q, A, d) does distinguish them. Rotating a stored response is legitimate for a rigidly rotated copy. It cannot update a response to a new shape.
The paper’s concrete picture is template reuse: compute a reference opening’s directional response once, then keep only frame, area and depth for positioning copies. That is fine until a copy is stretched or sheared. Computing Q from B loses nothing; the loss happens later, at the point where the shape coordinates are thrown away.
A failed scalar formula is a different failure
One could replace the whole angular response by a single attenuation factor times P0. That is exact for every illumination only if V is constant over the front hemisphere, which a channel generally is not. But showing that this formula fails by changing the light does not prove its geometric inputs are insufficient; a cleverer calculation might use the same inputs differently. The paper’s counterexamples avoid this trap by fixing the light and changing the geometry without changing the descriptor.
The answer depends on the lighting family
If the allowed illuminations are combinations of a finite set of basis functions φ1 … φq, it is enough to keep the response moments
because for L = Σ αjφj the answer is Σ αjmj. Nine exact moments suffice when the light contains only spherical-harmonic degrees zero to two, even though the opening’s response has sharp edges. A narrow cone is not in that space, so success there says nothing about a narrow source.
At the other extreme, for convex planar mouths with a common normal and a known normal extrusion, the complete family of ideal responses determines the shape up to translation and reflection in a point. That follows from an established theorem about the covariogram (Unit 8). It is not a claim that a few noisy measurements can reconstruct a shape, nor that some number of stored coordinates is minimal.
The practical conclusion. Retain what the chosen observable and lighting family can detect. Once that information is present, its numerical accuracy becomes the next question.
The dual question
The same argument works with the roles swapped: fix the geometry and reduce the lighting input. If two illuminations share a lighting descriptor, every calculation given only the geometry and that descriptor has worst error at least ½|T(g, L1) − T(g, L2)|. Unit 6 applies this with a descriptor made of 145 incident patch fluxes.
Check yourself
State in one sentence what you must exhibit to prove a descriptor insufficient.
Two allowed geometries with identical descriptors whose required answers differ under one allowed illumination.
A colleague fits a neural network to predict T from (Q, A, d) and the full illumination, and reports 0.5 pp error on a test set. Does that contradict the paper?
No. The floor applies to the worst case over a family that contains both members of a counterexample pair. A test set that happens not to contain such pairs can show small error. Feed the network the square and the rectangle under the 2° cone and it must miss one of them by more than 7.8125 pp, because it receives identical inputs.
True answers are 0.30 and 0.42. What single prediction minimises the worst absolute error, and what is that error? What about relative error?
guide exercise Absolute: the midpoint 0.36, with error 0.06. Relative: the harmonic mean 2 × 0.30 × 0.42 / 0.72 = 0.35, with relative error 0.12/0.72 ≈ 16.7% on both.
Why does the paper insist on a finite cone as well as a single ray?
Because a one-direction source has zero angular extent and could be dismissed as unphysical. The cone is an ordinary bounded source, and the gap survives with a proof that does not rely on numerical integration.
Nine degree-two moments predict some cases almost perfectly. Does that make them a sufficient record?
Sufficient for illuminations confined to degrees zero to two, yes. Not for a family that includes narrow cones, which lie outside that space.
Is “keep the complete B and v” the paper’s recommendation?
It is always sufficient under the stated law, but it need not be the smallest useful record. The recommendation is to keep what the observable and lighting family can detect.