After this unit you can
- Define the covariogram and connect it to the visible fraction
- Write the transmitted power for a general convex mouth
- State the polygon certificate and say what it does not cover
- Compute visibility through a stack of thin masks
- Reproduce the tall-and-wide stop counterexample and its floor
The covariogram
For a convex mouth M, slide a copy of it by a displacement z and measure what still overlaps:
That function is the covariogram of M. Under the same assumptions as before (parallel mouths, uniform angular field, straight rays, absorbing walls) the visible fraction is cM(z)/A. For the unit square it is the product of two tents, which is Equation 5.
With depth d, tangential offset t, z = dp − t and r(z) = (z + t, d), the displacement integral of Unit 2 becomes
where M − M is the set of all differences of two points of the mouth: the displacements for which any overlap remains.
A check against a classical formula
For two equal coaxial disks of radius a under isotropic light, with u = d/a, Sullivan’s two-disk factor gives T = 2/(2 + u² + u√(4 + u²)). Radial integration of the formula above at u = ¼, 1 and 4 agreed with it to within 7.85 × 10⁻⁷.
guide exercise At u = 1 (depth equal to radius): 2/(3 + √5) ≈ 0.382. A round hole as deep as its radius passes about 38% of isotropic light.
The covariogram’s square root is concave on M − M (a consequence of the Brunn–Minkowski inequality). The covariogram itself need not be: for the unit square, c(t, t) = (1 − t)², whose midpoint value ¼ is below the average ½ of its endpoints.
This is also where the identifiability statement of Unit 3 comes from. For planar convex bodies, the covariogram determines the body up to translation and point reflection. That is a theorem about complete, exact responses.
A certificate for a fixed polygon
Keep a convex polygon M as a fixed template and let each opening be an affine image of it, evaluated through q = Wp + β as in Unit 4. Define bM(h) as the length of h times the width of M perpendicular to h.
Proposition 7.1 (fixed polygonal template). With 𝒰 the vertices of both slope supports,
The idea: sliding a copy of M by h can change its overlap with a fixed copy by at most the strip it sweeps, which is bM(h). That bound is convex in h, so again the worst case over a support sits at a vertex. For the unit square bM(h) = |hx| + |hy|, and the proposition reduces to the corner bound of Unit 4.
| Template | Vertices per support | Certified bound | Largest change seen on a 21 × 21 grid |
|---|---|---|---|
| Unit square | 4 | 33/4000 | 0.0030534 |
| Right triangle | 6 | 13/2000 | 0.0020687 |
| Irregular pentagon | 10 | 21/4000 | 0.0016491 |
The grid values show how much slack the certificate has at sampled points. The proof is what supplies the all-direction guarantee.
The template must be exact. The proposition covers rounding the affine map while keeping the polygon unchanged. Perturbing the polygon’s own vertices changes the covariogram and needs a separate bound.
Stops inside the channel
Real optical stages are rarely a single tube. For ideal thin parallel masks Mj at heights zj above a reference mouth M0, a ray starting at x passes mask j at x + zjp. It gets through only if it clears every mask:
The key word is same: one starting point has to pass through every projected mask. Overlapping each pair separately is not enough.
Counterexample 3: a tall stop and a wide stop
Unit squares at z = 0 and z = 1, with a centred rectangle inserted at z = ½. In one stack the middle stop is ½ wide and 1 tall; in the other it is 1 wide and ½ tall. The two stacks share every mask area and centroid, all depths, the same axes and both end masks. With X = [1 − |px|]+ and Y = [1 − |py|]+:
Working it
At p = (½, 0): X = ½, Y = 1. Tall: ½ × 1 = ½. Wide: ½ × ½ = ¼.
Over the 2° cone of Unit 3 the gap stays above 219/1280. Any single prediction from the shared record therefore errs by more than 219/2560, which is 8.55 percentage points, on one of the two stacks.
The converse of the daylight result. Unit 6 lost source position with the geometry exact. Here the source direction and both end masks are exact, and what is lost is the shape of a stop in the middle. Each example names the shared inputs, the missing coordinate and a lower bound on the error.
For polygonal stacks, the directions accepted from one starting point form a spherical polygon. That is where clipped spherical-harmonic integration (Unit 5) can enter an angular calculation. A circular source edge still needs separate handling, and whole-mouth flux still averages over starting points.
Check yourself
What is the covariogram of the unit square at z = (0.3, 0.2)?
guide exercise (1 − 0.3)(1 − 0.2) = 0.56. Dividing by the area 1 gives the visible fraction for that displacement.
Why does the polygon certificate use vertices of both supports again?
For the same reason as in Unit 4: outside both supports both responses vanish, inside either one the bound is a convex function of slope, and a convex function on a polygon peaks at a vertex. The decoded support is included because rounding may admit new directions.
In the stop example, the two stacks have the same middle-mask area. Why is that the point?
Because it shows that mask areas, centroids, depths and end masks together still do not determine the response. A summary built from those quantities is insufficient for this family.
Compute Vtall and Vwide at p = (0, ½).
guide exercise X = 1, Y = ½. Tall: min(1, ½) × ½ = ¼. Wide: 1 × min(½, ½) = ½. The roles swap with the direction, as symmetry demands.
Does covariogram uniqueness mean a camera could recover a mouth shape from a few readings?
No. It concerns the complete ideal response for convex planar mouths with a known normal extrusion. Finite, noisy, physically imperfect measurements are a different problem that the paper does not address.