Light experiment · F1
Turn the light across a slot.
Start along the long edge. Then turn the same slant across the narrow edge and watch the green area in each opening. It marks the rays that can reach the exit without hitting a wall.
Square
Rectangle
The rectangle’s long side leaves more of the path clear.
The colored area shows where parallel rays pass straight through. The model uses absorbing walls. Physical measurements are pending.
Adjust the angles
Open instrument · F1 / M01
How F1 will test the prediction
The square is 25 × 25 mm. The rectangle is 50 × 12.5 mm. Both are 25 mm deep. The reference mask sits at the exit, 25 mm from the entrance. In one R15 calculation with uneven illumination, the sample and mask give equal readings even though only 46.875% of the entering light reaches the exit. Why does the reference position matter?

Build the F1.
The engineering kit contains the editable Blender assembly, a GLB exchange model, seven STEP assemblies, machining sheets, the parts list and the acquisition tools.
Download engineering kitZIP · 5.89 MB · Verify SHA-256
Machine the cassette and references
Use the STEP assemblies with the shop drawings. Measure the finished openings and depth, then record the specimen identifiers.
Shop drawings · Technician sheets · EN / ARAssemble the reader and qualify the optics
Check the purchased parts against the bill of materials. Record source uniformity, alignment and detector response before comparing cassettes.
Parts list · Readout guide · Optics and collectionRecord the physical comparison
Measure the open reference at the entrance and at the exit with the same beam. Bound the emerging light that misses the detector. Measure each recess with its own open reference and background readings. Repeat after reseating. Retain the raw scans and record their uncertainty.
Blank measurement card · Interval instructions
Replay the prediction.
The published benchmark spreads the light across a cone with a 2° half-angle around the same central direction as the long-axis example. It predicts 49.1719% transmission for the square and 72.5153% for the rectangle at zero roll.
Read the protocol · Reference resultsFrom the extracted kit
Use Python 3 with NumPy installed. The first command writes a 66-case simulation. The remaining commands exercise synthetic records and emulated instrument controllers.
python3 prediction/run_bench.py --out my-replay
python3 measurement/interval_intake.py --self-test
python3 instrument/reader_selfcheck.py
python3 instrument/raster_selfcheck.py
F1 aims to measure the whole exit. If missed light is unbounded, report the sample-to-mask signal ratio over the scanned area. A physical test of R11’s matched-view result also needs a receiver with characterized angular acceptance. Read working revision 11.
Source & licences.
The F1/M01 release includes the instrument design, original acquisition software, prediction and measurement tools, and build documentation. The public engineering ZIP is the versioned source for this page.
Read the release notice · Kit README- Hardware design
- Blender and exchange geometry, STEP files, cassette generator and technician drawings. CERN-OHL-P-2.0.
- Instrument software
- Pico readout source, capture, raster and viewer code use the contributors’ MIT licence. The R9 prediction and interval scripts carry Mostafa Nasr’s MIT notice.
- Documentation & reference results
- Guides, templates, protocols, results and the Works reference image use CC BY 4.0. The Revision 9 study supplies the prediction replay. Third-party components and documents retain their own terms.