# Open Aperture F1 · Works engineering replication kit

Two mouths admit light through a 25 mm deep recess. Their open areas both measure 625 mm² in the drawings. Does replacing a 25 × 25 mm square with a 50 × 12.5 mm rectangle change how much light passes through when it comes in at an angle?

## Choose the file for your task

* Open **viewer/viewer.html** for the full assembled instrument from CN Works. Explore the base, source, aperture, references, receiver and console. Its 125 visible parts come from the issued Blender assembly.
* Open **assembly/Path_A_aperture_instrument_F1.blend** in Blender for the editable full instrument. **assembly/F1-Works-assembly.glb** is a self-contained, metre-scale interchange mesh of the same visible assembly. The native assembly also retains construction and hidden reference objects. For a repeatable conversion use `python3 assembly/export_works_glb.py viewer/works-bench.js F1.glb`.
* For machining, use **hardware/Path_A_mechanical_shop_sheets.pdf** and the **six STEP files in hardware/**. These millimetre solids cover the square and rectangular cassettes, one reference holder in three alternative states, and the installed fixture. **hardware/context/M01_square_installed_context.step** places the square cassette, fixture and undrilled reference base together in a 13-solid assembly. The STEP files and issued drawings govern the fabricated optical interfaces.
* Start an independent build with **hardware/BILL-OF-MATERIALS.txt**, the bilingual workshop field sheets **hardware/Path-A-Technician-Set-A1-EN-AR.pdf** and the readout, motion and acquisition guides in **instrument/**. Check the actual bought-in components before laying out their mount holes. The source, stage, console and receiver bodies in the complete instrument model describe integration envelopes.
* **provenance/assembly.json** records the issued full model's identity, visual inventory, envelope and conversion units. **provenance/files.json** maps each release artifact to its source. **SHA256SUMS.txt** verifies the extracted files.

## Replay the prediction first

Install Python 3 and NumPy in a virtual environment. From the root of this kit run:

    python3 prediction/run_bench.py --out my-replay
    python3 measurement/interval_intake.py --self-test
    cd instrument
    python3 reader_selfcheck.py
    python3 raster_selfcheck.py

The first command writes 66 ideal, simulated cases. Compare its summary with **prediction/published_summary.json**. At nominal zero roll, with a uniform circular beam tilted by atan(1/2) and a 2° half-angle, the full model predicts transmitted fractions of **0.491719** for the square and **0.725153** for the rectangle. A point source at the central angle describes a different experiment. The other commands exercise the arithmetic and instrument software on synthetic inputs. This release contains no physical transmission result from a machined pair.

## Build an independent copy

1. **Fabricate the measured parts.** Give the shop **hardware/Path_A_mechanical_shop_sheets.pdf** and the matching STEP solids. Use the mouth facing the receiver as the exit datum. Measure the assembled clear entrance and exit, depth, taper and alignment, wall finish, actual foil opening and thickness. Preserve the two masks and specimen IDs. If adapting a mount to a different purchased instrument, check fit, travel and optical clearances against that actual unit.
2. **Assemble and qualify the reader.** Start with **instrument/INSTRUMENT_BUILD.txt**, then **OPTICS_AND_COLLECTION.txt** for the source, monitor, scan area and angular response. **MOTOR_OPTION.txt** and **RUN_A_RASTER.txt** describe the optional supervised controller and its default offline plan. Keep the optics shrouded and prove travel limits and cable clearance before moving a real stage. Record source profile and uniformity at both mouths, detector linearity, collecting area, repeatability and background. The supplied USB/Pico checks use emulators.
3. **Freeze the comparison before opening the flux results.** State the source geometry, mask dimensions, as-built model, prediction intervals and randomization of the two specimens across independent reseats. Record IDs and the planned exclusions in a dated copy. Use matched open-mask scans bracketing each recess scan; acquire both a source-off dark and a source-on closed-mask background. Map both specimens across the entire exit field under matched illumination. See **instrument/OPTICS_AND_COLLECTION.txt** for pitch, area and settling checks. Retain raw readouts, stage positions, monitor, timestamps, uncertainty sources, and rejected exposures as well as every accepted scan.
4. **Report what the intervals establish.** Follow **measurement/INSTRUCTIONS.txt** after reducing the detector maps. For each specimen compute its corrected area-weighted recess signal divided by its own matched mask signal, multiplied by the actual mask-throughput correction. Include bounds covering the measurements jointly. Save a copy of **blank_measurement_card.json** inside measurement, fill in the evidence, and run **python3 measurement/interval_intake.py measurement/my_card.json** from the kit root. Keep inconclusive cases. A claim about one common reduced input also requires its actual serialized records and the common calibrated illumination described in that guide.

## Change the geometry

Open the STEP sources directly or regenerate the two four-bar cassettes from the dimension parameters. Install the optional Python CAD binding used for this release:

    python3 -m pip install cadquery-ocp-novtk==7.9.3.1.1
    python3 hardware/make_cassette.py --width 25 --height 25 --depth 25 --output my-square.step
    python3 hardware/make_cassette.py --width 50 --height 12.5 --depth 25 --output my-rectangle.step

Boolean comparisons of each regenerated nominal cassette with the supplied exchange found zero residual solid volume in both directions. Changing a mouth creates a new specimen with its own matched mask, predictions and inspection record.

## Share a replication

Publish or supply the kit version and SHA-256, changes to the drawings, photos of the as-built geometry and geometry survey, dated prospective prediction, raw maps, reduction code, calibration and uncertainty records, and outcome. Identify simulated, pilot and physical records separately. Share null or inconclusive results the same way as successful ones. The [partner brief](https://partners.corridornumerics.com/) can help organize an independent run. [Revision 9 and the scientific supplement](https://doi.org/10.5281/zenodo.23985228) define the model and its physical comparison. The [Experiment C companion](https://doi.org/10.5281/zenodo.24001923) examines the limits of a different, conditional measurement.

**SHA256SUMS.txt** covers all other files in this archive. Run **shasum -a 256 -c SHA256SUMS.txt** in its extracted root to verify. Hardware is available under CERN-OHL-P-2.0, software under MIT, and documentation under CC BY 4.0. See **NOTICE.txt** and **LICENSES/** for attribution and scope.