Corridor Numerics العربية
Open studio · Giza, Egypt

Optics research · Working paper R15

Which light reaches the detector?

In a model square channel, the sample and open exit reference give equal readings. Yet only 15/32 of the power entering the channel gets through. Section 9 lets you work through both calculations.

Digital bench model with the light source, aperture holder and detector on the same axis.
Digital model of F1, the proposed bench for comparing entrance and exit readings.

Revision history

  1. R15Entrance power and the detector reading
  2. R14How many radius measurements suffice?
  3. R13Which errors come from missing geometry?
All revisions on Zenodo

What still needs a bench?

The F1 square and slot still await a calibrated physical comparison. Can you repeat the measurement with the same beam and record where you put the reference mask?

Contribute a repeat measurement

Path A · Revision 15 · 23 November 2026

Which light are we measuring?

Picture a slot 25 mm deep with a beam tilted along it. Some light hits a wall. Some clears the exit. Some of that emerging light can pass beside the detector. A transmission percentage needs to say where the light was counted.

What R14 predicts

The square and the slot have equal area and depth. With uniform illumination across the entrance and the beam tilted 26.6° from the normal along the slot, about 49.17% of entering light clears the square and 72.52% clears the slot. The model assumes absorbing walls and uniform radiance within a cone of 2° half-angle.

What R15 establishes

For four simulated circular channels, radius readings at the two ends and midpoint suffice to predict transmission within one percentage point under the stated wall-curvature, measurement-error and illumination assumptions. A separate example gives identical readings at every angle under uniform illumination when the channel is reversed. With the same localized beam, one orientation passes all the light and the other blocks it.

What F1 will measure

We’ll measure the light through an open reference at the entrance and again at the exit under the same tilted beam. We’ll also bound how much emerging light misses the detector. The physical square–slot comparison is still pending.

Revision 14 · 21 November 2026

How many measurements does a light channel need?

Two smooth channels can have the same openings and enclosed volume, yet one passes an oblique beam that the other blocks. The position of a narrowing can matter even when the channels transmit the same power on axis.

If each radius reading has a known error and the wall curvature has a known bound, we can enclose the power reaching a partly visible exit. In three simulated broad channels, five measurement stations, including both ends, bounded the prediction error to one percentage point. For the narrow horn, seventeen was the first tested count to meet that target under its specified illumination.

The scientific question

Which errors can more computation fix?

Three different problems can produce an inaccurate prediction. Treating them separately tells us what to improve, and what additional evidence is needed.

Information lost
before calculation.

Equal area, frame and depth do not determine the optical response. When distinct openings have the same record, every predictor using that record inherits a worst-case error.

Shape stored at
finite precision.

A useful record can keep the missing shape. Bounds connect the precision of that record to a specified transmission error, so storage can be chosen for the question being asked.

The wrong
observable checked.

A whole-exit flux check can pass while a receiver with a restricted field of view fails. Angular resolution must be assessed against what the receiver actually collects.

Selected findings

Claims with
defined limits.

These numbers come from analytical bounds and numerical fixtures in the paper’s ideal straight-ray, absorbing-wall model. They are not measured device performance.

>7.81 pp

Area and depth leave a consequential ambiguity.

The aspect-ratio example forces a worst-case transmission error exceeding 7.81 percentage points for a record that omits the distinguishing shape. The skew example gives a separate lower bound exceeding 2.50 points.

28,951 bytes

Controlled precision can reduce a shape record.

A 2,000-aperture fixture uses 28,951 bytes instead of 103,921 under a 0.01 directional-transmission budget. This comparison excludes pose and reader costs; it is not a whole-system compression result.

600 / 600

A total-flux test is only one test.

Depth-eight whole-exit cases all meet the study’s one-percentage-point target. Restricted-view results meet it in 1,307 of 1,890 cases. The receiver’s acceptance changes the question.

≥8.58 pp

An angular cell can hide different light fields.

The full-Klems-cell example yields an ambiguity of at least 8.58 percentage points. Refining an integration rule does not recover angular information that the input has already discarded.

Read the working paper and its companion evidence for the cases, assumptions, bounds and scope. The study does not establish general speed gains, a universal failure of an approximation method, or hardware efficiency.

The visible difference

Equal area.
Unequal passage.

The square is 25 × 25 mm. The rectangle is 50 × 12.5 mm. Each has an area of 625 mm². They share a frame and, initially, a depth of 25 mm.

At a 45° tilt across the width, a ray moves sideways by 25 mm between the faces. The square has no clear overlap. Half the rectangle remains open.

Turn the tilt across the height and the rectangle’s advantage can reverse. Shape is directional information.

The two drawings always use the same scale.
The dashed exit is shifted into the entrance plane along the rays.

Interactive calculationIdeal · not measured

Tilt the light. Read the overlap.

Square25 × 25 mm
50.0%of open-mouth flux
Rectangle50 × 12.5 mm
75.0%of open-mouth flux

Open mouth Shifted exit Clear path

Change the shared geometry and pencil direction
26.6°
−60° to +60° from the normal
25 mm
0–75 mm · both openings

Square 50.0%; rectangle 75.0% of matched open-mouth flux.

Static example: depth 25 mm, tilt atan(1/2) ≈ 26.565° across X. JavaScript enables the controls; the explanation and reference values do not need it.

Directional pencil prediction. Straight rays, absorbing walls; illumination uniform across each mouth. Equal area: 625 mm². These controls do not calculate a finite cone or a physical measurement.

Read the model

Follow the rays. Find the overlap.

  1. 01

    Follow the rays.

    A direction gives a sideways displacement across the recess. Straight rays either clear the walls or meet an absorbing surface.

  2. 02

    Find the overlap.

    Shift one mouth into the other’s plane along those rays. The common area is the set of clear paths. Divide it by the mouth area.

  3. 03

    Weight the directions.

    A light field contains many directions. Average their visible fractions using incident radiance and the projected-area cosine.

The straight rectangular recess

V = (1 − d|px|/w)+ (1 − d|pz|/h)+

Here (a)+ = max(a, 0). Width is w, height is h and depth is d. In bench coordinates, +Y is the front normal and X–Z is the mouth plane: px = sx/sy, pz = sz/sy, for sy > 0.

This is visibility for one direction, not a universal lamp or detector model. There is no reflection, refraction, diffraction, glazing or scattering in this idealisation.

From visibility
to total flux.

For radiance L(s) that is spatially uniform over the mouth for each direction, normalized transmission is the radiance-and-cosine-weighted average of V:

T = ∫ L(s) μ+ V(s) dΩ / ∫ L(s) μ+ dΩ

Here μ = n · s and the open-mouth flux in the denominator must be positive. A directional pencil isolates one direction, so its normalized transmission equals V. Total transmitted flux is not a spot voltage or an arbitrary detector reading.

Different inputs, different numbers

One ray is not a cone.

The controls above calculate a directional pencil. The fixed comparison here also includes a uniform angular cone with a 2° half-angle, centred at atan(1/2) ≈ 26.565° across the width.

Both fixed cases use depth 25 mm and the same 625 mm² mouths. The cone has uniform radiance within its angular support and is spatially uniform over each mouth. Its total-flux average includes the cosine weight.

The table stays fixed when you move the controls. Cone values are rounded numerical estimates from the R9 aspect-ratio companion, not measured results or certified bounds on the displayed digits.

Fixed reference comparison / normalized transmission
Illumination / evidenceSquareRectangle
Directional pencilIdeal, at the cone axis0.500000.75000
Uniform 2° coneIdeal, numerical average0.491720.72515
Physical benchMeasurements not yet collected—Not measured—Not measured

Read the published assumptions and computational evidence

How much reaches the receiver?

Revision 11 / Computational result

A solar-sized source illuminates a straight, absorbing 4:1 rectangular recess. Its center is at a polar angle of 35° and an azimuth of 0°. A receiver pointed in the straight-through direction accepts the same 0.266° half-angle as the source.

Fraction of unblocked incident disk power
What is collectedPower
Ideal straight-through reference64.677%
Depth-ten XML, whole exit64.669%
Same XML, matching receiver55.975%

Merging is disabled. The XML assigns 8.693 percentage points of incident power to directions outside the receiver. Its whole-exit total meets the one-percentage-point target, while its matched-view prediction misses by about 8.702 points. Differences use the unrounded data.

Read R11, section 6.4 · Download the case tables and XMLs.

A practical consequence

Choose the record
for the question.

Specify the source, the geometry and the receiver before choosing an approximation. Then check information sufficiency, representation precision and numerical convergence separately.

Evidence still to collect

A position is not
a light field.

F1 build under way / Measurements pending

Physical transmission results have not yet been collected. The open bench is a digital assembly and replication resource, not evidence that the instrument satisfies the model.

Source and lens-housing coordinates alone do not establish spatially uniform L(s). A finite source can couple position and direction, giving a field L(x, s), rather than the direction-only field used above.

Before comparison, the illumination needs independent characterisation, justified bounds on spatial uniformity, or a position-and-direction model. The receiver’s collection area, angular acceptance and spectral response must also match the total-flux observable.

Measure the as-built mouths and depth; use each insert’s matched open reference and dark readings; record alignment, reseating and uncertainty. Neither CAD coordinates nor a nominal source cone validate those steps.

Related question: different light fields can produce the same pair of sensor readings. Read the Experiment C companion. Source-dependent conclusions need independent source evidence.

Read, calculate, question

Learn the argument
one ray at a time.

The ten-unit study guide works through the examples by hand. It remains explicitly tied to Revision 11; its section, equation and table references have not been renumbered for later revisions.