F1 instrument planning, ideal source and parameter sensitivity panel, 2026-11-05. Write this protocol before computing outputs. The two as-designed mouths (25x25 and 50x12.5 mm) have depth 25 mm. Orthogonal straight walls, common known normal, predicted uniform circular cone across both mouths, full exit flux, zero scatter. Baseline source tilt atan(1/2), half angle 2 deg, lateral direction along bench X. Test each nominal shape at 0, 17, 31 degree rolls (the latter two hypothetical; require fixture qualification). For each take nominal, and one-at-a-time changes: source tilt +/-0.25 degree and half-width +/-0.25 degree, clear width/height/depth each +/-0.10 mm. These are sensitivity increments, not installed tolerances, probabilities or uncertainty bounds. Also model 0.10 mm and 0.50 mm thickness reference masks as short same-mouth ideal prisms; the former nominal A1 sheet, latter prior traveler placeholder. Compare raw same-mask ratio versus normalized corrected T. Compare exact W and W rounded to binary16; flag exact nominal equality. Negative controls are digital comparison models: equal-area centered square and a hypothetical swapped specimen ID. Keep the specimens distinct. Evaluate deterministic cap Gauss-Legendre in cos(theta) with azimuth midpoint rules, axis direction always in the symmetry plane; primary 96x768, verify 48x384 and 96x384. Test baseline pair difference against the revision-9 closed-form gap. Output numeric case records, summary and input hash. Numerical study only; no measured inputs, procurement or CAD edits.